● Configure safety circuits external to the programmable controller to ensure that the entire system
operates safely even when a fault occurs in the external power supply or the programmable
controller. Failure to do so may result in an accident due to an incorrect output or malfunction.
(1) Emergency stop circuits, protection circuits, and protective interlock circuits for conflicting
operations (such as forward/reverse rotations or upper/lower limit positioning) must be
configured external to the programmable controller.
(2) When the programmable controller detects an abnormal condition, it stops the operation and all
outputs are:
• Turned off if the overcurrent or overvoltage protection of the power supply module is
activated.
• Held or turned off according to the parameter setting if the self-diagnostic function of the
CPU module detects an error such as a watchdog timer error.
Also, all outputs may be turned on if an error occurs in a part, such as an I/O control part, where
the CPU module cannot detect any error. To ensure safety operation in such a case, provide a
safety mechanism or a fail-safe circuit external to the programmable controller. For a fail-safe
circuit example, refer to "General Safety Requirements" in the MELSEC-L CPU Module User's
Manual (Hardware Design, Maintenance and Inspection).
(3) Outputs may remain on or off due to a failure of a component such as a relay and transistor in an
output circuit. Configure an external circuit for monitoring output signals that could cause a
serious accident.
● In an output circuit, when a load current exceeding the rated current or an overcurrent caused by a
load short-circuit flows for a long time, it may cause smoke and fire. To prevent this, configure an
external safety circuit, such as a fuse.
● Configure a circuit so that the programmable controller is turned on first and then the external power
supply. If the external power supply is turned on first, an accident may occur due to an incorrect
Q系列PLC存储卡 Q3MEM-8MBS-SET
模块 A1SJ71ME81
Q系列PLC线性快闪存储卡 Q2MEM-2MBF
MES接口模块附件 GT05-MEM-256MC
闪存卡 QD81MEM-4GBC
CF卡 GT05-MEM-2GC
Q系列PLC存储卡用适配器 Q2MEM-ADP
可选功能板 GT15-MESB48M
CF卡 GT05-MEM-128MC
存储卡 Q1MEM-64S
Q系列PLC存储卡 Q3MEM-4MBS-SET
CF卡 GT05-MEM-1GC
Q系列编程器ATA卡 Q2MEM-16MBA
Q系列PLC内存卡 Q2MEM-1MBS
Q系列PLC存储卡 Q3MEM-8MBS
可选功能板 GT16-MESB
存储卡适配器 GT05-MEM-ADPC
CF卡 GT05-MEM-8GC
MES接口模块附件 GT05-MEM-128MC
闪存卡 QD81MEM-8GBC
Q系列编程器SRAM卡用电池 Q2MEM-BAT
闪存卡 QD81MEM-1GBC
Q系列PLC内存卡 Q2MEM-2MBS
Q系列编程器ATA卡 Q2MEM-32MBA
闪存卡 QD81MEM-512MBC
CF卡 GT05-MEM-256MC
Q系列PLC内存卡 Q3MEM-4MBS
模块 AJ71ME81
MES接口模块 QJ71MES96
CF卡 GT05-MEM-512MC
三菱 MELSEC 三菱-MELSEC-L IO 模块 用户手册     三菱 MELSEC 三菱-MELSEC-L IO 模块 用户手册
相关下载